Blue Diamond Brush Cutter Severe Duty Series 2 72 in, 150cc: specs & which machines can run it
Brush Cutter rated for 16–26 GPM. Good fit on 42 of the 64 loaders we track.
Specs
- Type
- Brush Cutters
- Flow class
- standard
- Min flow
- 16 GPM
- Max flow
- 26 GPM
- Min pressure
- not published
- Max pressure
- 4500 PSI
- Min HP
- not published
- Max HP
- not published
- Width
- 72 in
- Weight
- 2250 lb
Source: https://www.bluediamondattachments.com/attachments/brush-cutter-severe-duty-series-2 (official)
Placeholder · affiliate link
Affiliate / “get a quote” link for Blue Diamond Brush Cutter Severe Duty Series 2 72 in, 150cc goes here. No affiliate program is connected yet.
Placeholder · featured partner slot
Featured maker / dealer slot — Blue Diamond dealers. Reserved for a future paid placement. No partner has been signed. This box is intentionally empty.
Verify with your dealer. Results come from published specs and our matching rules. They are not a guarantee. Coupler type, case-drain line, electrical connectors, auxiliary options, relief settings and model year all matter. Confirm with the dealer and the attachment maker before you buy or run anything.
Machines that can run the Blue Diamond Brush Cutter Severe Duty Series 2 72 in, 150cc
42 good fit20 marginal2 won't run
- Good fitASV RT-135 (standard flow)20 GPM is inside the 16-26 GPM range. 3300 PSI is within the head's pressure rating.
- Good fitASV RT-135 Forestry (standard flow)20 GPM is inside the 16-26 GPM range. 3300 PSI is within the head's pressure rating.
- Good fitASV RT-75 (standard flow)22.6 GPM is inside the 16-26 GPM range. 3300 PSI is within the head's pressure rating.
- Good fitASV VT-100 (standard flow)23 GPM is inside the 16-26 GPM range. 3481 PSI is within the head's pressure rating.
- Good fit
- Good fitASV VT-80 (standard flow)24.7 GPM is inside the 16-26 GPM range. 3771 PSI is within the head's pressure rating.
- Good fitBobcat S64-2 (standard flow)17.6 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat S650 (standard flow)23 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat S66-2 (standard flow)17.6 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat S76-2 (standard flow)23.3 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat S770 (standard flow)23 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat S86-2 (standard flow) · details23 GPM is inside the 16-26 GPM range. 4061 PSI is within the head's pressure rating.
- Good fitBobcat T64-2 (standard flow) · details17.6 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat T650 (standard flow)23 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat T66-2 (standard flow)17.6 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat T76-2 (standard flow)23.3 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat T770 (standard flow)23 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating.
- Good fitBobcat T86-2 (standard flow) · details23 GPM is inside the 16-26 GPM range. 4061 PSI is within the head's pressure rating.
- Good fit
- Good fit
- Good fit
- Good fit
- Good fitCat 289D3 (standard flow)23 GPM is inside the 16-26 GPM range. 3336 PSI is within the head's pressure rating.
- Good fitCat 299D3 (standard flow)23 GPM is inside the 16-26 GPM range. 3335 PSI is within the head's pressure rating.
- Good fitCat 299D3 XE (standard flow)23 GPM is inside the 16-26 GPM range. 3335 PSI is within the head's pressure rating.
- Good fitJohn Deere 325G (standard flow)21 GPM is inside the 16-26 GPM range. 3450 PSI is within the head's pressure rating.
- Good fitJohn Deere 331G (standard flow)23.5 GPM is inside the 16-26 GPM range. 3450 PSI is within the head's pressure rating.
- Good fitJohn Deere 333G (standard flow)25 GPM is inside the 16-26 GPM range. 3450 PSI is within the head's pressure rating.
- Good fitKubota SVL75-3 (standard flow)19.2 GPM is inside the 16-26 GPM range. 3185 PSI is within the head's pressure rating.
- Good fitKubota SVL97-2 (standard flow)23.1 GPM is inside the 16-26 GPM range. 3553 PSI is within the head's pressure rating.
- Good fitNew Holland C327 (standard flow)24.2 GPM is inside the 16-26 GPM range. 3046 PSI is within the head's pressure rating.
- Good fitNew Holland C332 (standard flow)24.2 GPM is inside the 16-26 GPM range. 3046 PSI is within the head's pressure rating.
- Good fitNew Holland C334 (standard flow)24.2 GPM is inside the 16-26 GPM range. 3046 PSI is within the head's pressure rating.
- Good fitNew Holland C337 (standard flow)24.2 GPM is inside the 16-26 GPM range. 3046 PSI is within the head's pressure rating.
- Good fitNew Holland C345 (standard flow)24.2 GPM is inside the 16-26 GPM range. 3450 PSI is within the head's pressure rating.
- Good fitNew Holland C362 (standard flow)24.2 GPM is inside the 16-26 GPM range. 3450 PSI is within the head's pressure rating.
- Good fitNew Holland L328 (standard flow)24.2 GPM is inside the 16-26 GPM range. 3046 PSI is within the head's pressure rating.
- Good fitNew Holland L334 (standard flow)24.2 GPM is inside the 16-26 GPM range. 3450 PSI is within the head's pressure rating.
- Good fitTakeuchi TL10V2 (standard flow)18.8 GPM is inside the 16-26 GPM range. 3191 PSI is within the head's pressure rating.
- Good fitTakeuchi TL11R3 (standard flow)23.1 GPM is inside the 16-26 GPM range. 3481 PSI is within the head's pressure rating.
- Good fitTakeuchi TL12R2 (standard flow)23.3 GPM is inside the 16-26 GPM range. 3481 PSI is within the head's pressure rating.
- Good fitTakeuchi TL12V2 (standard flow)23.2 GPM is inside the 16-26 GPM range. 3481 PSI is within the head's pressure rating.
- MarginalASV RT-65 (standard flow)21.4 GPM is inside the 16-26 GPM range. 3771 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 2000 lb rated operating capacity.
- MarginalBobcat S450 (standard flow)16.7 GPM is inside the 16-26 GPM range. 3300 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 1370 lb rated operating capacity.
- MarginalBobcat S590 (standard flow)17.1 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 2000 lb rated operating capacity.
- MarginalBobcat T450 (standard flow)16.7 GPM is inside the 16-26 GPM range. 3300 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 1490 lb rated operating capacity.
- MarginalBobcat T595 (standard flow)17.1 GPM is inside the 16-26 GPM range. 3500 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 2100 lb rated operating capacity.
- Marginal
- MarginalCASE TR270B (standard flow)24.2 GPM is inside the 16-26 GPM range. Head weighs 2250 lb, more than the 1890 lb rated operating capacity.
- MarginalCASE TR310B (standard flow)24.2 GPM is inside the 16-26 GPM range. Head weighs 2250 lb, more than the 2170 lb rated operating capacity.
- MarginalCat 239D3 (standard flow)18 GPM is inside the 16-26 GPM range. 3336 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 1530 lb rated operating capacity.
- MarginalCat 249D3 (standard flow)18 GPM is inside the 16-26 GPM range. 3336 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 1740 lb rated operating capacity.
- MarginalCat 259D3 (standard flow)20 GPM is inside the 16-26 GPM range. 3336 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 2010 lb rated operating capacity.
- MarginalCat 279D3 (standard flow)23 GPM is inside the 16-26 GPM range. 3336 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 2220 lb rated operating capacity.
- MarginalJohn Deere 317G (standard flow)17 GPM is inside the 16-26 GPM range. 3450 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 2125 lb rated operating capacity.
- MarginalKubota SVL65-2 (standard flow)17.4 GPM is inside the 16-26 GPM range. 3263 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 2100 lb rated operating capacity.
- MarginalNew Holland L316 (standard flow)18.4 GPM is inside the 16-26 GPM range. 3046 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 1600 lb rated operating capacity.
- MarginalNew Holland L318 (standard flow)20.6 GPM is inside the 16-26 GPM range. 3046 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 1800 lb rated operating capacity.
- MarginalNew Holland L320 (standard flow)20.6 GPM is inside the 16-26 GPM range. 3046 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 2000 lb rated operating capacity.
- MarginalNew Holland L321 (standard flow)24.2 GPM is inside the 16-26 GPM range. 3046 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 2100 lb rated operating capacity.
- MarginalTakeuchi TL6R (standard flow)17.7 GPM is inside the 16-26 GPM range. 2988 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 1840 lb rated operating capacity.
- MarginalTakeuchi TL8R2 (standard flow)20 GPM is inside the 16-26 GPM range. 3046 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 2115 lb rated operating capacity.
- Won't runASV RT-50 (standard flow)13.3 GPM is well below the 16 GPM minimum. 3000 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 1400 lb rated operating capacity.
- Won't runBobcat S70 (standard flow)8.9 GPM is well below the 16 GPM minimum. 2000 PSI is within the head's pressure rating. Head weighs 2250 lb, more than the 760 lb rated operating capacity.