What mulchers can a Cat 299D3 run?
30 forestry mulchers in our database are a good fit for the Cat 299D3. Below: every mulcher, brush cutter and other hydraulic attachment we track, checked against this machine's published flow, pressure and horsepower.
Cat 299D3 specs
- Type
- CTL
- Engine HP
- 98 gross (SAE J1995)
- Operating weight
- 11464 lb
- Rated operating capacity
- 3480 lb 35% tipping load
| Aux circuit | Flow GPM | Pressure PSI |
|---|---|---|
| Standard flow | 23 | 3335 |
| High flow | 32 | 4061 |
Source: official doc (Cat specalog AEHQ8269-04) hosted by Cat dealer Zeppelin · Note: High flow on 279D3/289D3/299D3 is High Flow XPS.
| Attachment type | Good | Marginal | Won't run |
|---|---|---|---|
| Forestry Mulchers | 30 | 16 | 6 |
| Brush Cutters | 17 | 7 | 6 |
| Stump Grinders | 2 | 3 | 1 |
| Cold Planers | 7 | 1 | 0 |
| Trenchers | 4 | 0 | 0 |
| Auger Drives | 5 | 6 | 2 |
| Snow Blowers | 5 | 0 | 5 |
Placeholder · featured partner slot
Featured maker / dealer slot — Cat 299D3 dealers. Reserved for a future paid placement. No partner has been signed. This box is intentionally empty.
Verify with your dealer. Results come from published specs and our matching rules. They are not a guarantee. Coupler type, case-drain line, electrical connectors, auxiliary options, relief settings and model year all matter. Confirm with the dealer and the attachment maker before you buy or run anything.
Forestry Mulchers on the Cat 299D3
30 good fit16 marginal6 won't run
- Good fitFecon Blackhawk BK7618 (high flow, confidence high) · details32 GPM is inside the 30-50 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitFAE UML/SSL SONIC-175 (high flow, confidence high)32 GPM is inside the 30-53 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitFAE UML/SSL VT-175 (high flow, confidence high) · details32 GPM is inside the 30-53 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitFAE UML/SSL/BL SONIC-175 (high flow, confidence high)32 GPM is inside the 30-53 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitFAE UML/SSL/BL VT-175 (high flow, confidence high)32 GPM is inside the 30-53 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitFecon Bull Hog BH85SS (high flow, confidence high)32 GPM is inside the 30-50 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitCat HM316 Mulcher (drum) maker-listed (high flow, confidence high) · details32 GPM is inside the 31-33 GPM range. 4061 PSI is within the head's pressure rating.
- Good fitFAE UML/SSL SONIC-150 (high flow, confidence high)32 GPM is inside the 30-53 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitFAE UML/SSL VT-150 (high flow, confidence high)32 GPM is inside the 30-53 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitFAE UML/SSL/BL SONIC-150 (high flow, confidence high)32 GPM is inside the 30-53 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitFAE UML/SSL/BL VT-150 (high flow, confidence high)32 GPM is inside the 30-53 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitFecon Blackhawk BK6218 (high flow, confidence high)32 GPM is inside the 30-50 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitFecon Bull Hog BH74SS (high flow, confidence high)32 GPM is inside the 30-50 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitDenis Cimaf DAF-150D (standard flow, confidence high)23 GPM meets the 23 GPM minimum required flow. 3335 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitCat HM115 Mulcher maker-listed (standard flow, confidence high)23 GPM is inside the 20-23 GPM range. 3335 PSI is within the head's pressure rating.
- Good fitFecon Bull Hog BH62SS (high flow, confidence high)32 GPM is inside the 30-50 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitCat HM316 Mulcher (bite limiter) maker-listed (high flow, confidence high) · details32 GPM is inside the 31-33 GPM range. 4061 PSI is within the head's pressure rating.
- Good fitPrinoth Grizzly M450s-1900 (high flow, confidence medium)32 GPM is inside the 24.6-52.8 GPM range. 98 HP is within the head's horsepower range.
- Good fitPrinoth Grizzly M450s-1600 (standard flow, confidence medium)23 GPM is inside the 22.5-52.8 GPM range. 98 HP is within the head's horsepower range.
- Good fitBlue Diamond Disc Mulcher 60 in, 150cc (high flow, confidence medium)32 GPM is inside the 32-45 GPM range.
- Good fitBlue Diamond HD Drum Mulcher 60 in (standard flow, confidence medium)23 GPM is inside the 22-46 GPM range.
- Good fit
- Good fit
- Good fitDiamond Mowers Drum Mulcher DC Pro (standard flow, confidence medium)23 GPM is inside the 17-40 GPM range.
- Good fit
- Good fitBobcat Disc Mulcher 48DCM-G88 (standard flow, confidence medium)23 GPM is inside the 23-29 GPM range.
- Good fitBlue Diamond Disc Mulcher 44 in, 100cc (standard flow, confidence medium)23 GPM is inside the 20-30 GPM range.
- Good fitBlue Diamond Disc Mulcher 44 in, 150cc (high flow, confidence medium)32 GPM is inside the 30-44 GPM range.
- Good fitDiamond Mowers Drum Mulcher DC Pro X2 (standard flow, confidence medium)23 GPM is inside the 23-50 GPM range.
- Good fitDiamond Mowers Drum Mulcher OD Pro X2 (high flow, confidence medium)32 GPM is inside the 27-50 GPM range.
- MarginalDenis Cimaf DAF-180D (high flow, confidence high)32 GPM is up to 10% below the 35 GPM minimum - expect reduced speed/power. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- MarginalBobcat Drum Mulcher 72 in 2-speed (high flow, confidence high)Maker publishes only a 45 GPM maximum; 32 GPM is under 75% of it - confirm minimum with dealer. Machine relief 4061 PSI exceeds the head's 4000 PSI max - confirm relief setting with dealer.
- MarginalLoftness Carbide Cutter 71G4 (high flow, confidence high)32 GPM is up to 10% below the 33 GPM minimum - expect reduced speed/power. 4061 PSI is within the head's pressure rating.
- MarginalBobcat Drum Mulcher 61 in 1-speed (high flow, confidence high)32 GPM is at or under the 40 GPM maximum (no minimum published). Machine relief 4061 PSI exceeds the head's 4000 PSI max - confirm relief setting with dealer.
- MarginalBobcat Drum Mulcher 61 in 2-speed (high flow, confidence high)Maker publishes only a 45 GPM maximum; 32 GPM is under 75% of it - confirm minimum with dealer. Machine relief 4061 PSI exceeds the head's 4000 PSI max - confirm relief setting with dealer.
- MarginalBobcat Drum Mulcher 61 in 2-speed DCR (high flow, confidence high)Maker publishes only a 45 GPM maximum; 32 GPM is under 75% of it - confirm minimum with dealer. Machine relief 4061 PSI exceeds the head's 4000 PSI max - confirm relief setting with dealer.
- MarginalLoftness Carbide Cutter 61G4 (high flow, confidence high)32 GPM is up to 10% below the 33 GPM minimum - expect reduced speed/power. 4061 PSI is within the head's pressure rating.
- MarginalFecon Bull Hog RK6015 (standard flow) (standard flow, confidence high)23 GPM is inside the 17-34 GPM range. 3335 PSI is within the head's pressure rating. 98 HP is above the head's 75 HP maximum.
- MarginalCat HM215 Mulcher (standard flow, confidence high)23 GPM is up to 10% below the 25 GPM minimum - expect reduced speed/power. 3335 PSI is within the head's pressure rating.
- MarginalBobcat Drum Mulcher 50 in 2-speed (high flow, confidence high)Maker publishes only a 45 GPM maximum; 32 GPM is under 75% of it - confirm minimum with dealer. Machine relief 4061 PSI exceeds the head's 4000 PSI max - confirm relief setting with dealer.
- MarginalBobcat Drum Mulcher 50 in 2-speed DCR (high flow, confidence high)Maker publishes only a 45 GPM maximum; 32 GPM is under 75% of it - confirm minimum with dealer. Machine relief 4061 PSI exceeds the head's 4000 PSI max - confirm relief setting with dealer.
- MarginalFecon Bull Hog RK5015 (standard flow) (standard flow, confidence high)23 GPM is inside the 17-34 GPM range. 3335 PSI is within the head's pressure rating. 98 HP is above the head's 75 HP maximum.
- MarginalPrinoth Grizzly M450s-2200 (high flow, confidence medium)32 GPM is inside the 31.7-66 GPM range. 98 HP is just under the 100 HP minimum.
- MarginalBlue Diamond SD Drum Mulcher 79 in (high flow, confidence medium)32 GPM is up to 10% below the 35 GPM minimum - expect reduced speed/power.
- MarginalBlue Diamond SD Drum Mulcher 70 in (high flow, confidence medium)32 GPM is up to 10% below the 35 GPM minimum - expect reduced speed/power.
- MarginalBlue Diamond SD Drum Mulcher 60 in (high flow, confidence medium)32 GPM is up to 10% below the 35 GPM minimum - expect reduced speed/power.
- Won't runDenis Cimaf DAF-180E (standard flow, confidence high)23 GPM is well below the 50 GPM minimum. 3335 PSI is within the head's pressure rating. 98 HP is well below the 125 HP minimum.
- Won't runCat HM418 Mulcher (bite limiter) (standard flow, confidence high)23 GPM is well below the 40 GPM minimum. 3335 PSI is within the head's pressure rating.
- Won't runCat HM418 Mulcher (drum) (standard flow, confidence high)23 GPM is well below the 40 GPM minimum. 3335 PSI is within the head's pressure rating.
- Won't runCat HM416 Mulcher (drum) (standard flow, confidence high)23 GPM is well below the 36 GPM minimum. 3335 PSI is within the head's pressure rating.
- Won't runCat HM112 Mulcher (standard flow, confidence high)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit. 3335 PSI is within the head's pressure rating.
- Won't runCat HM416 Mulcher (bite limiter) (standard flow, confidence high)23 GPM is well below the 40 GPM minimum. 3335 PSI is within the head's pressure rating.
Brush Cutters on the Cat 299D3
17 good fit7 marginal6 won't run
- Good fitBlue Diamond Brush Cutter 84 in Dual, 125cc (standard flow, confidence high) · details23 GPM is inside the 23-30 GPM range. 3335 PSI is within the head's pressure rating.
- Good fitBlue Diamond Brush Cutter Extreme Duty Closed Front 72 in, 160cc (standard flow, confidence high)23 GPM is inside the 16-26 GPM range. 3335 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitBlue Diamond Brush Cutter Extreme Duty Open Front 72 in, 160cc (standard flow, confidence high)23 GPM is inside the 16-26 GPM range. 3335 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitBlue Diamond Brush Cutter Extreme Duty Open Front 72 in, 200cc (high flow, confidence high)32 GPM is inside the 27-35 GPM range. 4061 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitBlue Diamond Brush Cutter Severe Duty Series 2 72 in, 150cc (standard flow, confidence high)23 GPM is inside the 16-26 GPM range. 3335 PSI is within the head's pressure rating.
- Good fitBlue Diamond Brush Cutter Severe Duty Series 2 72 in, 200cc (high flow, confidence high)32 GPM is inside the 27-35 GPM range. 4061 PSI is within the head's pressure rating.
- Good fitBlue Diamond HD Closed Front Brush Cutter 72 in, 160cc (standard flow, confidence high)23 GPM is inside the 19-26 GPM range. 3335 PSI is within the head's pressure rating.
- Good fitBlue Diamond Brush Cutter Extreme Duty Open Front 60 in, 200cc (standard flow, confidence high)23 GPM is inside the 23-40 GPM range. 3335 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Good fitBobcat HD Brush Cutter 86 in high flow (high flow, confidence medium) · details32 GPM is inside the 30-37 GPM range.
- Good fit
- Good fitBobcat HD Brush Cutter 74 in high flow (high flow, confidence medium)32 GPM is inside the 26-37 GPM range.
- Good fitBobcat HD Brush Cutter 74 in standard flow (standard flow, confidence medium)23 GPM is inside the 17-23 GPM range.
- Good fit
- Good fitBobcat Brushcat 72 in standard flow (standard flow, confidence medium)23 GPM is inside the 15-26 GPM range.
- Good fit
- Good fitBobcat Brushcat 66 in standard flow (standard flow, confidence medium)23 GPM is inside the 15-24 GPM range.
- Good fitBobcat HD Brush Cutter 62 in standard flow (standard flow, confidence medium)23 GPM is inside the 17-23 GPM range.
- MarginalBlue Diamond Brush Cutter 84 in Dual, 80cc (standard flow, confidence high)23 GPM is above the 22 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3335 PSI is within the head's pressure rating.
- MarginalBlue Diamond Brush Cutter Extreme Duty Closed Front 72 in, 200cc (high flow, confidence high)32 GPM is inside the 27-35 GPM range. Machine relief 4061 PSI exceeds the head's 3600 PSI max - confirm relief setting with dealer. 98 HP is within the head's horsepower range.
- MarginalBlue Diamond Brush Cutter Severe Duty Series 2 72 in, 250cc (high flow, confidence high)32 GPM is up to 10% below the 35 GPM minimum - expect reduced speed/power. 4061 PSI is within the head's pressure rating.
- MarginalBlue Diamond Brush Cutter Extreme Duty Closed Front 60 in, 100cc (standard flow, confidence high)23 GPM is above the 22 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3335 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- MarginalBlue Diamond Brush Cutter Extreme Duty Open Front 60 in, 100cc (standard flow, confidence high)23 GPM is above the 22 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3335 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- MarginalBlue Diamond HD Closed Front Brush Cutter 60 in, 100cc (standard flow, confidence high)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3335 PSI is within the head's pressure rating.
- MarginalBobcat HD Brush Cutter 62 in high flow (high flow, confidence medium)32 GPM is above the 31 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- Won't runBlue Diamond Brush Cutter Extreme Duty Closed Front 72 in, 250cc (standard flow, confidence high)23 GPM is well below the 36 GPM minimum. 3335 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Won't runBlue Diamond Brush Cutter Extreme Duty Open Front 72 in, 250cc (standard flow, confidence high)23 GPM is well below the 36 GPM minimum. 3335 PSI is within the head's pressure rating. 98 HP is within the head's horsepower range.
- Won't runBlue Diamond HD Closed Front Brush Cutter 60 in, 80cc (standard flow, confidence high)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3335 PSI is within the head's pressure rating.
- Won't runBobcat Brushcat 54 in (35cc) (standard flow, confidence medium)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat Brushcat 54 in (50cc) (standard flow, confidence medium)23 GPM is far above the 18 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat Brushcat 44 in (30cc) (standard flow, confidence medium)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
Stump Grinders on the Cat 299D3
2 good fit3 marginal1 won't run
- Good fitBlue Diamond Stump Grinder Extreme Duty 24 in wheel, 75cc (PN 104120) (standard flow, confidence medium)23 GPM is inside the 20-25 GPM range.
- Good fitBlue Diamond Stump Grinder Extreme Duty 26 in wheel, 130cc (PN 104210) (high flow, confidence medium)32 GPM is inside the 29-33 GPM range.
- MarginalBlue Diamond Stump Grinder Extreme Duty 24 in wheel, 60cc (PN 104110) (standard flow, confidence medium)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalBlue Diamond Stump Grinder Extreme Duty 24 in wheel, 90cc (PN 104130) (standard flow, confidence medium)23 GPM is up to 10% below the 25 GPM minimum - expect reduced speed/power.
- MarginalBlue Diamond Stump Grinder Extreme Duty 26 in wheel, 150cc (PN 104220) (high flow, confidence medium)32 GPM is up to 10% below the 33 GPM minimum - expect reduced speed/power.
- Won't runBlue Diamond Stump Grinder Extreme Duty 26 in wheel, 170cc (PN 104230) (standard flow, confidence medium)23 GPM is well below the 39 GPM minimum.
Cold Planers on the Cat 299D3
7 good fit1 marginal0 won't run
- Good fitBlue Diamond Cold Planer Extreme Duty Series 2, 48 in (high flow, confidence high)32 GPM is inside the 32-50 GPM range. 4061 PSI is within the head's pressure rating.
- Good fitBlue Diamond Cold Planer Extreme Duty Series 2, 40 in (high flow, confidence high)32 GPM is inside the 29-45 GPM range. 4061 PSI is within the head's pressure rating.
- Good fitBlue Diamond Cold Planer Extreme Duty Series 2, 30 in (high flow, confidence high)32 GPM is inside the 29-45 GPM range. 4061 PSI is within the head's pressure rating.
- Good fitBlue Diamond Cold Planer Extreme Duty Series 2, 24 in (high flow, confidence high)32 GPM is inside the 27-40 GPM range. 4061 PSI is within the head's pressure rating.
- Good fitBlue Diamond Cold Planer Extreme Duty Series 2, 20 in (high flow, confidence high)32 GPM is inside the 27-40 GPM range. 4061 PSI is within the head's pressure rating.
- Good fitBlue Diamond Cold Planer Extreme Duty Series 2, 18 in (high flow, confidence high)32 GPM is inside the 27-40 GPM range. 4061 PSI is within the head's pressure rating.
- Good fitBlue Diamond Cold Planer Extreme Duty Series 2, 16 in (standard flow, confidence high)23 GPM is inside the 17-30 GPM range. 3335 PSI is within the head's pressure rating.
- MarginalBlue Diamond Cold Planer Extreme Duty Series 2, 14 in (standard flow, confidence high)23 GPM is above the 21 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3335 PSI is within the head's pressure rating.
Trenchers on the Cat 299D3
4 good fit0 marginal0 won't run
- Good fitBlue Diamond Trencher Extreme Duty, 12 in cut (PN 131577-00) (standard flow, confidence high)23 GPM is inside the 16-30 GPM range. 3335 PSI is within the head's pressure rating.
- Good fitBlue Diamond Trencher Extreme Duty, 10 in cut (PN 131576-00) (standard flow, confidence high)23 GPM is inside the 16-30 GPM range. 3335 PSI is within the head's pressure rating.
- Good fitBlue Diamond Trencher Extreme Duty, 8 in cut (PN 131575-00) (standard flow, confidence high)23 GPM is inside the 16-30 GPM range. 3335 PSI is within the head's pressure rating.
- Good fitBlue Diamond Trencher Extreme Duty, 6 in cut (PN 131574-00) (standard flow, confidence high)23 GPM is inside the 16-30 GPM range. 3335 PSI is within the head's pressure rating.
Auger Drives on the Cat 299D3
5 good fit6 marginal2 won't run
- Good fitDanuser EP1530 Auger Drive (standard flow, confidence high)23 GPM is inside the 15-30 GPM range. 3335 PSI is within the head's pressure rating.
- Good fitDanuser EP2035 Auger Drive (standard flow, confidence high)23 GPM is inside the 20-35 GPM range. 3335 PSI is within the head's pressure rating.
- Good fitPengo CS 35-25 Auger Drive (standard flow, confidence high)23 GPM is at or under the 25 GPM maximum (no minimum published). 3335 PSI is within the head's pressure rating.
- Good fitPengo CS 38-30 Auger Drive (standard flow, confidence high)23 GPM is at or under the 30 GPM maximum (no minimum published). 3335 PSI is within the head's pressure rating.
- Good fitPengo CS 41-25 Auger Drive (standard flow, confidence high)23 GPM is at or under the 25 GPM maximum (no minimum published). 3335 PSI is within the head's pressure rating.
- MarginalDanuser EP1020 Auger Drive (standard flow, confidence high)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3335 PSI is within the head's pressure rating.
- MarginalPengo CS 22-20 Auger Drive (standard flow, confidence high)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3335 PSI is within the head's pressure rating.
- MarginalPengo CS 28-22 Auger Drive (standard flow, confidence high)23 GPM is above the 22 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3335 PSI is within the head's pressure rating.
- MarginalPengo CS 39-37 Auger Drive (standard flow, confidence high)Maker publishes only a 37 GPM maximum; 23 GPM is under 75% of it - confirm minimum with dealer. 3335 PSI is within the head's pressure rating.
- MarginalPengo CS 49-36 Auger Drive (standard flow, confidence high)Maker publishes only a 36 GPM maximum; 23 GPM is under 75% of it - confirm minimum with dealer. 3335 PSI is within the head's pressure rating.
- MarginalPengo CS 49-45 Auger Drive (standard flow, confidence high)Maker publishes only a 45 GPM maximum; 23 GPM is under 75% of it - confirm minimum with dealer. 3335 PSI is within the head's pressure rating.
- Won't runDanuser EP615 Auger Drive (standard flow, confidence high)23 GPM is far above the 15 GPM maximum - wrong motor size for this circuit. 3335 PSI is within the head's pressure rating.
- Won't runPengo CS 20-17 Auger Drive (standard flow, confidence high)23 GPM is far above the 17 GPM maximum - wrong motor size for this circuit. 3335 PSI is within the head's pressure rating.
Snow Blowers on the Cat 299D3
5 good fit0 marginal5 won't run
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Won't runBobcat Snowblower SB36x96 (standard flow, confidence medium)23 GPM is well below the 36 GPM minimum.
- Won't runBobcat Snowblower SB36x86 (standard flow, confidence medium)23 GPM is well below the 36 GPM minimum.
- Won't runBobcat Snowblower SB26x56 (standard flow, confidence medium)23 GPM is far above the 17 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat Snowblower SB26x48 (standard flow, confidence medium)23 GPM is far above the 17 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat Snowblower SB26x36 (standard flow, confidence medium)23 GPM is far above the 17 GPM maximum - wrong motor size for this circuit.
Weekly email: new heads, price changes & recalls
PLACEHOLDER. This form is not connected to any email service and sends nothing.