Blue Diamond Stump Grinder Extreme Duty 24 in wheel, 60cc (PN 104110): specs & which machines can run it
Stump Grinder rated for 16–20 GPM. Good fit on 20 of the 64 loaders we track.
Specs
- Type
- Stump Grinders
- Flow class
- standard
- Min flow
- 16 GPM
- Max flow
- 20 GPM
- Min pressure
- not published
- Max pressure
- not published
- Min HP
- not published
- Max HP
- not published
- Width
- not published
- Weight
- 640 lb
Maker lists 'best flow' range; requires case drain line.
Source: https://www.bluediamondattachments.com/uploads/specs/Stump-Grinder-Extreme-Duty-062823.pdf (official)
Placeholder · affiliate link
Affiliate / “get a quote” link for Blue Diamond Stump Grinder Extreme Duty 24 in wheel, 60cc (PN 104110) goes here. No affiliate program is connected yet.
Placeholder · featured partner slot
Featured maker / dealer slot — Blue Diamond dealers. Reserved for a future paid placement. No partner has been signed. This box is intentionally empty.
Verify with your dealer. Results come from published specs and our matching rules. They are not a guarantee. Coupler type, case-drain line, electrical connectors, auxiliary options, relief settings and model year all matter. Confirm with the dealer and the attachment maker before you buy or run anything.
Machines that can run the Blue Diamond Stump Grinder Extreme Duty 24 in wheel, 60cc (PN 104110)
20 good fit18 marginal26 won't run
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- Good fit
- MarginalASV RT-65 (standard flow)21.4 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalASV RT-75 (standard flow)22.6 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalASV VT-100 (standard flow)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalASV VT-75 (standard flow)21.4 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalBobcat S650 (standard flow)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalBobcat S770 (standard flow)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalBobcat S86-2 (standard flow)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- Marginal
- MarginalBobcat T650 (standard flow)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalBobcat T770 (standard flow)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalBobcat T86-2 (standard flow)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalCat 279D3 (standard flow)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalCat 289D3 (standard flow)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalCat 299D3 (standard flow)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalCat 299D3 XE (standard flow)23 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalJohn Deere 325G (standard flow)21 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalNew Holland L318 (standard flow)20.6 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalNew Holland L320 (standard flow)20.6 GPM is above the 20 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- Won't run
- Won't runASV VT-80 (standard flow)24.7 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't run
- Won't runBobcat S76-2 (standard flow)23.3 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat T76-2 (standard flow)23.3 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR270B (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR310B (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR340B (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV370B (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV450B (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV620B (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runJohn Deere 331G (standard flow)23.5 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runJohn Deere 333G (standard flow)25 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runKubota SVL97-2 (standard flow)23.1 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C327 (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C332 (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C334 (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C337 (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C345 (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C362 (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland L321 (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland L328 (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland L334 (standard flow)24.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runTakeuchi TL11R3 (standard flow)23.1 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runTakeuchi TL12R2 (standard flow)23.3 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.
- Won't runTakeuchi TL12V2 (standard flow)23.2 GPM is far above the 20 GPM maximum - wrong motor size for this circuit.