Blue Diamond HD Closed Front Brush Cutter 60 in, 80cc: specs & which machines can run it
Brush Cutter rated for 11–16 GPM. Good fit on 1 of the 64 loaders we track.
Specs
- Type
- Brush Cutters
- Flow class
- standard
- Min flow
- 11 GPM
- Max flow
- 16 GPM
- Min pressure
- not published
- Max pressure
- 3600 PSI
- Min HP
- not published
- Max HP
- not published
- Width
- 60 in
- Weight
- 940 lb
Source: https://www.bluediamondattachments.com/attachments/brush-cutter-heavy-duty (official)
Placeholder · affiliate link
Affiliate / “get a quote” link for Blue Diamond HD Closed Front Brush Cutter 60 in, 80cc goes here. No affiliate program is connected yet.
Placeholder · featured partner slot
Featured maker / dealer slot — Blue Diamond dealers. Reserved for a future paid placement. No partner has been signed. This box is intentionally empty.
Verify with your dealer. Results come from published specs and our matching rules. They are not a guarantee. Coupler type, case-drain line, electrical connectors, auxiliary options, relief settings and model year all matter. Confirm with the dealer and the attachment maker before you buy or run anything.
Machines that can run the Blue Diamond HD Closed Front Brush Cutter 60 in, 80cc
1 good fit15 marginal48 won't run
- Good fit
- MarginalBobcat S450 (standard flow)16.7 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3300 PSI is within the head's pressure rating.
- MarginalBobcat S590 (standard flow)17.1 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- MarginalBobcat S64-2 (standard flow)17.6 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- MarginalBobcat S66-2 (standard flow)17.6 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- MarginalBobcat T450 (standard flow)16.7 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3300 PSI is within the head's pressure rating.
- MarginalBobcat T595 (standard flow)17.1 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- Marginal
- MarginalBobcat T64-2 (standard flow)17.6 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- MarginalBobcat T66-2 (standard flow)17.6 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3500 PSI is within the head's pressure rating.
- MarginalCat 239D3 (standard flow)18 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3336 PSI is within the head's pressure rating.
- MarginalCat 249D3 (standard flow)18 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3336 PSI is within the head's pressure rating.
- MarginalJohn Deere 317G (standard flow)17 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3450 PSI is within the head's pressure rating.
- MarginalKubota SVL65-2 (standard flow)17.4 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3263 PSI is within the head's pressure rating.
- MarginalNew Holland L316 (standard flow)18.4 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 3046 PSI is within the head's pressure rating.
- MarginalTakeuchi TL6R (standard flow)17.7 GPM is above the 16 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed. 2988 PSI is within the head's pressure rating.
- Won't runASV RT-135 (standard flow)20 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3300 PSI is within the head's pressure rating.
- Won't runASV RT-135 Forestry (standard flow)20 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3300 PSI is within the head's pressure rating.
- Won't runASV RT-65 (standard flow)21.4 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. Machine relief 3771 PSI exceeds the head's 3600 PSI max - confirm relief setting with dealer.
- Won't runASV RT-75 (standard flow)22.6 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3300 PSI is within the head's pressure rating.
- Won't runASV VT-100 (standard flow)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3481 PSI is within the head's pressure rating.
- Won't runASV VT-75 (standard flow)21.4 GPM is far above the 16 GPM maximum - wrong motor size for this circuit.
- Won't runASV VT-80 (standard flow)24.7 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. Machine relief 3771 PSI exceeds the head's 3600 PSI max - confirm relief setting with dealer.
- Won't runBobcat S650 (standard flow)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3500 PSI is within the head's pressure rating.
- Won't runBobcat S70 (standard flow)8.9 GPM is well below the 11 GPM minimum. 2000 PSI is within the head's pressure rating. Head weighs 940 lb, more than the 760 lb rated operating capacity.
- Won't runBobcat S76-2 (standard flow)23.3 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3500 PSI is within the head's pressure rating.
- Won't runBobcat S770 (standard flow)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3500 PSI is within the head's pressure rating.
- Won't runBobcat S86-2 (standard flow)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. Machine relief 4061 PSI exceeds the head's 3600 PSI max - confirm relief setting with dealer.
- Won't runBobcat T650 (standard flow)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3500 PSI is within the head's pressure rating.
- Won't runBobcat T76-2 (standard flow)23.3 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3500 PSI is within the head's pressure rating.
- Won't runBobcat T770 (standard flow)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3500 PSI is within the head's pressure rating.
- Won't runBobcat T86-2 (standard flow)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. Machine relief 4061 PSI exceeds the head's 3600 PSI max - confirm relief setting with dealer.
- Won't runCASE TR270B (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR310B (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR340B (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV370B (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV450B (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV620B (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit.
- Won't runCat 259D3 (standard flow)20 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3336 PSI is within the head's pressure rating.
- Won't runCat 279D3 (standard flow)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3336 PSI is within the head's pressure rating.
- Won't runCat 289D3 (standard flow)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3336 PSI is within the head's pressure rating.
- Won't runCat 299D3 (standard flow)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3335 PSI is within the head's pressure rating.
- Won't runCat 299D3 XE (standard flow)23 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3335 PSI is within the head's pressure rating.
- Won't runJohn Deere 325G (standard flow)21 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3450 PSI is within the head's pressure rating.
- Won't runJohn Deere 331G (standard flow)23.5 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3450 PSI is within the head's pressure rating.
- Won't runJohn Deere 333G (standard flow)25 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3450 PSI is within the head's pressure rating.
- Won't runKubota SVL75-3 (standard flow)19.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3185 PSI is within the head's pressure rating.
- Won't runKubota SVL97-2 (standard flow)23.1 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3553 PSI is within the head's pressure rating.
- Won't runNew Holland C327 (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C332 (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C334 (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C337 (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland C345 (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3450 PSI is within the head's pressure rating.
- Won't runNew Holland C362 (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3450 PSI is within the head's pressure rating.
- Won't runNew Holland L318 (standard flow)20.6 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland L320 (standard flow)20.6 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland L321 (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland L328 (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.
- Won't runNew Holland L334 (standard flow)24.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3450 PSI is within the head's pressure rating.
- Won't runTakeuchi TL10V2 (standard flow)18.8 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3191 PSI is within the head's pressure rating.
- Won't runTakeuchi TL11R3 (standard flow)23.1 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3481 PSI is within the head's pressure rating.
- Won't runTakeuchi TL12R2 (standard flow)23.3 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3481 PSI is within the head's pressure rating.
- Won't runTakeuchi TL12V2 (standard flow)23.2 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3481 PSI is within the head's pressure rating.
- Won't runTakeuchi TL8R2 (standard flow)20 GPM is far above the 16 GPM maximum - wrong motor size for this circuit. 3046 PSI is within the head's pressure rating.